Military Technology For Fire Protection

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsAerosol Type Fire Extinguisher

Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g

Good quality Aerosol Fire Fighting System for sales
Good quality Aerosol Fire Fighting System for sales
Trusted seller, on time delivery for our sample orders.

—— Armando Costa

Fireless is definitely valued for car engine room auto fires suppression, ,my customer satisfied with your products.

—— Edward Deanda

we have done demo to customers, fireless is competitive to other brand, smaller size and protecting larger space! good product!

—— j***a

I'm Online Chat Now

Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g

China Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g supplier
Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g supplier Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g supplier Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g supplier Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g supplier

Large Image :  Automotive Aerosol Type Fire Extinguisher / Aerosol Fire Extinguishing Generators 10g

Product Details:

Place of Origin: Jiangsu
Brand Name: Fireless
Certification: CE
Model Number: Fireless 0.3

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Negotation
Packaging Details: 100Nos. per box, packaged volume (59*48*22)cm
Delivery Time: 1-6weeks( depends on QTY,samples in stock)
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 20000 sets per month
Contact Now
Detailed Product Description
Item: Advanced Technology Aerosol Type Fire Extinguisher With 10g Agent Type: Advanced Technology Aerosol Type Fire Extinguisher
Agent Quantity: 10g Application: Small Space
Executive Standard: GA499.1-2010, GJB150A-2009 Extinguishing Fire Class: A,B,C,E,
High Light:

condensed aerosol fire suppression

,

aerosol systems fire suppression

Advanced Technology Aerosol Type Fire Extinguisher With 10g Agent

 

Since the phase out of Halon extinguishers in the 1980s, hot aerosol fire suppression technology has gained much attention. Unlike traditional inert gas, foam, water mist and Halon fire suppression agents, hot aerosol fire extinguishing agents do not need to be driven out by pressurized gases and can extinguish class A, B, C, D and K fires at 30 to 200 g/m3. As substitutes for Halon agents, the ODP and GWP values of hot fire extinguishing aerosols are nearly zero, but those fine aerosol particles can cause adverse health effects once inhaled by human.

 

Technical details:

Item

Advanced Technology Aerosol Type Fire Extinguisher With 10g Agent

Working environment:

-50℃~+95℃

Nameplate yes
Agent 10g
Protected volume 0.3m³
Discharge time: 2S 2s
Discharge delay time: 1s
Thermal line Combustion rate: 6.4s/m
The water resistance of Thermal line: waterproof
Seismic performance Good
Insulation of shell Good
Shock resistance Good

 

Type inspection result:

  •  Test standard: GA 499.1 -2004
  •  Test institute: CNCF (China National Center for Quality Supervision and Test of Fixed Fire-fighting Systems and Fire-resisting Building Components)
  •  Test: Type inspection
  •  Appearance: The surface coating is uniform, smooth
  •  Fasteners:Solid, sheet metal stamping
  •  Material:The housing and all parts and components shall be of corrosion resistant materials and shall be corrosion resistant
  •  Thermal spacing of non - temperature limiting fire extinguishing devices:

Thermal spacing is 0.02m: maximum 65℃

Thermal spacing is 0.04m: maximum 55℃

Thermal spacing is 0.08m: maximum 50℃

  •  The surface temperature:

During discharging: 152℃maximum

After discharging: 90℃ maximum

  •  Fire extinguisher environmental adaptability:maximum+ 95℃ in high temperature/ maximum -50℃ in cold temperature
  •  Thermal line environmental adaptability:maximum+ 95℃ in high temperature/ maximum -50℃ in cold temperature
  •  Agent Electrical insulation: >3kv
  •  Toxicity :no
  •  Drop rate of dust:3.0g/m³
  •  Hygroscopicity of solid deposition:0.4m/m
  •  Insulation strength of solid precipitate: 3 megohm
  •  The PH of the aqueous solution:9.5

As for configurations of hot aerosol fire extinguishing devices, fixed or portable cylindrical canisters are the most common among generation II & III hot aerosol fire extinguishers across the world, while generation I hot aerosol fire suppression systems are integrated with the oil tank as a whole. Some countries like the U.S., Australia, Russia and China, etc. have already developed standards for manufacturing and quality control of hot aerosol fire extinguishing agents and norms for hot aerosol fire extinguishing system design under different fire protection scenarios.